Written with AI assistance and may contain mistakes. Verify against the official Transport Canada publications before relying on anything here.

PPL Tester

Freezing level

Freezing level is the height where the air cools to 0 °C. Below it the air is above freezing, so it marks where airframe icing becomes possible in cloud or precipitation.

Cool the surface temperature at the standard (ISA) lapse rate, 1.98 °C per 1000 ft (TC AIM AIR 1.5.1): freezing level (ft AMSL) = elevation + (surface temp ÷ 1.98) × 1000.

Use that standard rate, not the dry (3 °C) or saturated (1.5 °C) adiabatic rate (TC AIM RPA 3.2.22.8); those describe a rising parcel, not the air sitting in place.

Note: estimating the freezing level this way assumes the real air follows the standard lapse rate (a rule of thumb); the GFA icing/turbulence chart forecasts the actual freezing level directly (TC AIM MET 4.12).

Unit trap: freezing is 0 °C = 32 °F. A surface temperature in °F must be converted to °C first; the elevation may be in metres (×3.28 to feet).

Trap: the answer is height above sea level. Add the station elevation, do not stop at the height above the station.

References


Practice